line delay trigger
To configure a time value for the SONET/SDH line delay trigger, use the line delay trigger command in
SONET controller configuration mode. To return the command to its default setting, use the no form of this
command.
line delay trigger value
no line delay trigger
Syntax Description
Value, in milliseconds, for the SONET/SDH line delay trigger. The range is 0 to
60000.
value
Command Default
The default is 0, which means that there is no delay.
Command Modes
SONET controller configuration
Command History
ModificationRelease
This command was introduced.Release 3.9.0
Usage Guidelines
To use this command, you must be in a user group associated with a task group that includes appropriate task
IDs. If the user group assignment is preventing you from using a command, contact your AAA administrator
for assistance.
If the timer for the SONET/SDH line delay trigger expires, an alarm is raised.
Task ID
OperationsTask ID
read, writesonet-sdh
Examples
The following example shows how to set the SONET/SDH line delay trigger to 3000 milliseconds:
RP/0/RSP0/CPU0:router(config)# controller SONET 0/0/0/2
RP/0/RSP0/CPU0:router(config-sonet)# line delay trigger 3000
Cisco ASR 9000 Series Aggregation Services Router Interface and Hardware Component Command Reference,
Release 5.3.x
868
SONET Controller Commands on the Cisco ASR 9000 Series Router
line delay trigger