frame-relay lmi-t392dce
To set the Local Management Interface (LMI) polling verification timer on the DCE, use the frame-relay
lmi-t392dce command in interface configuration mode. To restore the default setting, use the no form of this
command.
frame-relay lmi-t392dce seconds
no frame-relay lmi-t392dce seconds
Syntax Description
Polling verification timer, in seconds. The range is from 5 to 30. The default is
15.
seconds
Command Default
The LMI polling verification timer is 15 seconds.
Command Modes
Interface configuration (config-if)
Command History
ModificationRelease
This command was introduced.Release 4.0.0
Usage Guidelines
To use this command, you must be in a user group associated with a task group that includes appropriate task
IDs. If the user group assignment is preventing you from using a command, contact your AAA administrator
for assistance.
The frame-relay lmi-t392dce command is used along with the frame-relay lmi-t391dte command to define
the condition that causes the link to be declared down.
The seconds value defined in this command must be greater than the polling verification timer defined in the
frame-relay lmi-t391 dte command.
This frame-relay lmi-n392dce command is available on Packet-over-SONET/SDH (POS), serial, and multilink
interfaces.
Task ID
OperationsTask ID
read, writefr
Cisco ASR 9000 Series Aggregation Services Router Interface and Hardware Component Command Reference,
Release 5.3.x
444
Frame Relay Commands on the Cisco ASR 9000 Series Router
frame-relay lmi-t392dce