Switch Management Commands 1994
• In class mode, the port limit is twice the class power.
• In dynamic mode, up to 62W may be delivered.
• In static mode, the port is limited to the configured limit.
Use this command only with devices that require up to 60W of power.
Command History
Introduced in version 6.3.0.1 firmware.
Example
This example configures forced 60W 4-pair power mode on interface Gi1/0/1
console#configure
console(config)#power inline management static
console(config)#interface gi/10/1
console(config-if-Gi1/0/1)#power inline four-pair forced
power inline limit
Use the power inline limit command to configure the type of power limit.
Use the no form of this command to set the power limit type to the default.
Syntax
power inline limit {user-defined limit|class|none}
no power inline limit
• user-defined limit—Allows the port to draw up to user-defined value. The
range is 3000-32000 milliwatts (mW) in two-pair mode. In four-pair mode,
the range is 3000-57000 milliwatts.
• class—Allows the port to draw up to the class-based limit.
• none—Allows the port to draw up to the maximum feed the power is
capable of delivering.
Default Configuration
In two-pair mode, the default power limit is 32000 milliwatts. In four-pair
mode, the default power limit is 57000 milliwatts.