Switch Management Commands 1998
console(config)#interface range Gi1/0/1-10
console(config-if)#power inline auto
console(config-if)#exit
console#show power inline
Unit Status
===========
Unit........................................... 1
Power.......................................... On
Total Power.................................... 500 Watts
Threshold Power................................ 450 Watts
Consumed Power................................. 0 Watts
Usage Threshold................................ 90%
Power Management Mode.......................... Dynamic
Power Detection Mode........................... dot3at+legacy
Port Configuration
==================
Port Powered Device State Priority Status Class Power[mW]
--------- ---------------------- ----- -------- ----------- ------ ---------
Gi1/0/1 auto Low Searching Unknown
Gi1/0/2 auto Low Searching Unknown
Gi1/0/3 auto Low Searching Unknown
Gi1/0/4 auto Low Searching Unknown
Command History
Description revised in version 6.3.1.5 release.
Description revised in version 6.3.1.6 release. Example revised in 6.4 release.
power inline powered-device
The power inline powered-device command adds a comment or description
of the powered device type to enable the user to remember what is attached
to the interface. To remove the description, use the no form of this command.
Syntax
power inline powered-device
pd-type
no power inline powered-device
• pd-type — Specifies the type of powered device attached to the
interface. (Range: 1–20 characters)