Switch Management Commands 1997
power inline management
Use the power inline management command in Global Configuration mode
to set the power management type. This command is used along with the
power inline priority
command. Use the no form of this command to set the
management mode to the default.
Syntax
power inline management [unit unit-id]{dynamic | static | class}
no power inline management [unit unit-id]
dynamic—Dynamic power management
static—Static power management
class—Class-based power management
unit-id—A stack unit ID.
Default Configuration
Default management is dynamic.
Command Mode
Global Configuration
User Guidelines
If no unit is specified, all members of the stack are configured. Static,
dynamic and class-based modes differ in how the available power is calculated
and how much power may be delivered to the Powered Device. Refer to the
PoE section in the User’s Configuration Guide for information on Powered
Device detection, power allocation methods, and the PoE guard band.
Example
In the following example, no port is specified so the command displays global
configuration and status of all the ports. Configure the global power
management scheme as dynamic with dot3at+legacy detection and enable
PoE capability on ports Gi1/0/1-10.
console(config)#power inline management dynamic
console(config)#power inline detection dot3at+legacy

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Dell N1100-ON and is the answer not in the manual?

Dell N1100-ON Specifications

General IconGeneral
Power SupplyInternal
ModelN1100-ON
TypeManaged
Form FactorRack-mountable
Uplink PortsSFP+
Power over Ethernet (PoE)No
LayerLayer 3
Jumbo Frame SupportYes
Operating Temperature0°C to 45°C

Related product manuals