EasyManuals Logo

Dell N1100-ON User Manual

Dell N1100-ON
2332 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #436 background imageLoading...
Page #436 background image
Layer 2 Switching Commands 436
• Operational Status—The MEP operational status
• MAC—The MAC address associated with the MEP.
Example
show ethernet cfm maintenance-points local level 1
---- ----- ---- ---- ------ ----- -------- ------ ----------- -----
MPID Level Type VLAN Port Dire- CC MEP- Operational MAC
ction Transmit Active Status
---- ----- ---- ---- ------ ----- -------- ------ ----------- -----
1 1 MEP 10 Gi1/0/1 UP Enabled True 00:02:bc:02:02:02
----- ---- ------ -----------------
Level Type Port MAC
----- ---- ------ -----------------
show ethernet cfm maintenance-points remote
Use the show ethernet cfm maintenance-points remote command to display
the configured remote maintenance points.
Syntax
show ethernet cfm maintenance-points remote {level 0-7 | domain domain-
name | detail [mac mac-address | mep mpid] [domain domain-name | level
0-7] [vlan vlan-id]}
• domain—Name of the maintenance domain (an alphanumeric string of
up to 43 characters in length).
• level—Maintenance association level
• mac-addr—
The destination MAC address for which the connectivity needs to
be verified. Either MEP ID or the MAC address option can be used.
• vlan-id—
A VLAN associated with the maintenance domain. Range: 1-4093.
• mpid—
The MEP ID from which the loopback message needs to be transmitted.
Default Configuration
This command has no default configuration.
Command Mode
Privileged Exec, Global Configuration mode and all Configuration submodes

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell N1100-ON and is the answer not in the manual?