Switch Management Commands 2170
To disconnect a remote session to the stack master established from a stack
member.
(Unit 2 - CLI unavailable - please connect to master on Unit 1)>connect 2
(Unit 2 - CLI unavailable - please connect to master on Unit 1)>
(Unit 2 - CLI unavailable - please connect to master on Unit 1)>connect 1
Stack-Master#
Stack-Master#exit
Stack-Master>exit
(Unit 2 - CLI unavailable - please connect to master on Unit 1)>
hardware profile portmode
Use the hardware profile portmode command in Interface Configuration
mode to configure a 40G port in 4x10G mode or 1x40G mode.
Use the no form of the command to return the port to the default mode
(1x40G).
Syntax
hardware profile portmode {1x40g|4x10g}
no hardware profile portmode
• 1x40g—Configure the port as a single 40G port using 4 lanes.
• 4x10g—Configure the port as four 10G ports, each on a separate lane.
This mode requires the use of a suitable 4x10G to 1x40g pigtail cable.
Default Configuration
By default, 40G ports are configured in 1x40G mode.
Command Mode
Interface Configuration mode
User Guidelines
This command is only available on the N4000 series switches. This command
can only be executed on the 40G interface. Entering this command on any of
the 4x10G interfaces (or any other 10G port) will give an error.