Layer 2 Switching Commands 434
• DevXconCCM—The MEP has received at least one CCM from either
another MAID or a lower MD level whose CCM interval has not yet timed
out.
Example
console#show ethernet cfm errors
----- ---- ---- --------- ------------ ------------ ----------- ----------
Level SVID MPID DefRDICcm DefMACStatus DefRemoteCCM DefErrorCCM DefXconCCM
----- ---- ---- --------- ------------ ------------ ----------- ----------
show ethernet cfm domain
Use the show ethernet cfm domain command to display the configured
parameters in a maintenance domain.
Syntax
show ethernet cfm domain {brief |domain-id}
• domain—Name of the maintenance domain (an alphanumeric string of
up to 43 characters in length).
Default Configuration
This command has no default configuration.
Command Mode
Privileged Exec, Global Configuration mode and all Configuration submodes
User Guidelines
This command has no user guidelines.
Example
console # show Ethernet cfm domain domain1
Domain Name : domain1
Level : 1
Total Services : 1
---- ----------------------------------- ------------------
VLAN ServiceName CC-Interval (secs)
---- ----------------------------------- ------------------
10 serv1 1