C4 User Manual
October 25, 2021 ©2021 Smartrise Engineering, Inc. All Rights Reserved Page 245
2. From the MISCELLANEOUS menu, scroll and select Enable Pit Inspection.
Figure 432: MISCELLANEOUS Menu – Enable Pit Inspection
3. From the ENABLE PIT INSPECTION menu, scroll and select On to enable pit inspection.
Figure 433: ENABLE PIT INSPECTION Menu
4. Scroll right and press Save.
29.11 Enable Landing Inspection
Enables the landing inspection operation on the controller. Input 502 on the MR board must be
used to toggle inspection operation ON/OFF. Dip 3B must also be enabled to use the operation.
The following procedure describes how to enable landing inspection.
1. Navigate to MAIN MENU | SETUP | MISCELLANEOUS. See Figure 58.
2. From the MISCELLANEOUS menu, scroll and select Enable Landing Inspection.
Figure 434: MISCELLANEOUS Menu – Enable Landing Inspection
3. From the ENABLE LANDING INSPECTION menu, scroll and select On to enable landing
inspection.
Figure 435: ENABLE LANDING INSPECTION Menu
4. Scroll right and press Save.