C4 User Manual
Page 250 ©2021 Smartrise Engineering, Inc. All Rights Reserved October 25, 2021
3. From the OOS menu, scroll and select Hourly Fault Limit.
Figure 448: OOS Menu – Hourly Fault Limit
4. From the HOURLY FAULT LIMIT menu, set the number of logged faults allowed per hour.
Figure 449: HOURLY FAULT LIMIT Menu
5. Scroll right and press Save.
29.13.3 Maximum Starts Per Minute
The maximum starts per minute is the number of times a car starts a run in automatic
operation within the maximum amount of runs per minute. If additional runs are attempted,
the car goes out of service until the hour window elapses.
The following procedure describes how to set the maximum starts per minute.
1. Navigate to MAIN MENU | SETUP | MISCELLANEOUS. See Figure 58.
2. From the MISCELLANEOUS menu, scroll and select OOS. See Figure 445.
3. From the OOS menu, scroll and select Maximum Starts Per Minute.
Figure 450: OOS Menu – Maximum Starts Per Minute
4. From MAXIMUM STARTS PER MINUTE menu, adjust the value as required for the
maximum runs per minute.
Figure 451: MAXIMUM STARTS PER MINUTE Menu