C4 User Manual
Page 310 ©2021 Smartrise Engineering, Inc. All Rights Reserved October 25, 2021
3. From the ALLOWPH2WITHOUTPH1 menu, scroll and select if the car is set to run in a
medical emergency.
Figure 616: ALLOWPH2WITHOUTPH1 Menu
4. Scroll right and press Save.
33.5.2 Exit Ph2 Any Floor
When Exit Ph2 any floor is active, the controller can exit EMS phase 2 at any floor. If set to On,
the car can only exit EMS Phase 2 on the floor where it entered EMS Phase 2.
The following procedure describes how the settings to allow for exit phase 2 at any floor.
1. Navigate to MAIN MENU | SETUP | EMS. See Figure 60.
2. From the EMS menu, scroll and select Exit Ph2 Any Floor.
Figure 617: EMS Menu – Exit Ph2 Any Floor
3. From the EXIT PH2 ANY FLOOR menu, scroll and select if the controller can exit phase 2
on any floor.
Figure 618: EXIT PH2 ANY FLOOR Menu
4. Scroll right and press Save.
33.5.3 Fire Overrides Ph1
The following procedure describes how to allow fire to override Phase 1 EMS operation.
1. Navigate to MAIN MENU | SETUP | EMS. See Figure 60.