Page 288 ©2021 Smartrise Engineering, Inc. All Rights Reserved October 25, 2021
3. From the MAIN RECALL menu, scroll and select Opening.
Figure 549: MAIN RECALL Menu – Opening
4. From the MAIN: USE REAR DOOR menu, enable or disable rear door.
Figure 550: MAIN: USE REAR DOOR Menu
5. Scroll right and press Save.
33.3.2 Alternate Recall
Sensors indicate if the fire is at the designated main recall floor. If the fire is on that floor, the
car then travels to a designated alternate landing.
33.3.2.1 Alternate Recall Floor
The following procedure describes how to set the designated landing.
1. Navigate to MAIN MENU | SETUP | FIRE. See Figure 57.
2. From the FIRE SERVICE menu, scroll and select Alt Recall.
Figure 551: FIRE SERVICE Menu – Alt Recall
3. From the ALT RECALL menu, scroll and select Floor.
Figure 552: ALT RECALL Menu – Floor