February, 2008
2-165
WorkCentre 5225, 5230
016-226, 016-227
Status Indicator Raps
Launch Version
016-226 S2X IIT Connection Error RAP
S2X cannot detect Video Clock sent from IIT.
Initial Actions
Power Off/On
Procedure
(1) Check IISS-S2X cable for disconnection.
(2) If NG, replace the cable.
(3) If still NG., to replace S2XIF Board.
(4) If still NG after (3) above is complete, to replace Ext Board.
(5) If still NG after (4) above is complete, to replace S2X Board.
016-227 S2X DDR Error RAP
S2X failed in Internal DDR Memory Write/Read Test.
Initial Actions
Power Off/On
Procedure
Replace S2X board.