February, 2008
4-46
WorkCentre 5225, 5230
REP 7.3.5, REP 7.3.6
Launch Version
Repairs and Adjustments
Replacement
1. Install each new roll by squeezing its shaft at both ends and sliding the roll into place.
2. Use your fingers to roll each roll in place to assure its movement.
3. Flip down the Upper Feeder Assembly.
4. Close the Feeder Top Cover of the HCF.
REP 7.3.6 HCF Feed Shaft
Parts List on PL 18.5
Removal
WARNING
To avoid personal injury or shock, do not perform repair or adjustment activities with
the power switch on or electrical power applied to the machine.
1. Remove the HCF Feeder. (REP 7.3.2)
2. Place the Feeder on a flat surface.
3. Open the Upper Feeder Assembly by releasing the green lever.
4. Remove the Nudger Roll by squeezing the roll’s shaft at both ends (with the thumb and
forefinger of one hand) and lifting the roll up and out of the HCF.
5. Remove the E-Ring and bearing on the Feed Shaft (at the Nudger Roll end of the shaft).
6. Move the bearing at the opposite end of the shaft to the right, and slide the Feed Shaft to
the right to remove.
Replacement
1. To install, carry out the removal steps in reverse order.