Status Indicator Raps
116-348 Redirector RAP
A system function recall error is detected by the Redirector.
Initial Actions
Power Off/On
Procedure
Pull out and insert or replace the DIMM (PL 9.2).
If the problem persists, replace the ESS PWB (PL 9.2).
116-349 SIF RAP
An error occurred using the SIF (Source Input Format) function.
Initial Actions
Power Off/On
Procedure
Pull out and insert or replace the DIMM (PL 9.2).
If the problem persists reload Software (ADJ 9.3.1).