February, 2008
2-323
WorkCentre 5225, 5230
024-345, 024-346
Status Indicator Raps
Launch Version
024-345 IOT-ESS Communication Failure 5 RAP
A transmission failure occurred, the Check Code of the sent Message Packet is incorrect.
Initial Actions
Refer to BSD 3.1.
Procedure
Check that P/Js 402 on the MCU PWB (PL 9.1) and P/J 310 on the ESS PWB (PL 9.2) are
securely connected.
If the problem persists reload Firmware (ADJ 9.3.1).
024-346 IOT-ESS Communication Failure 6 RAP
A transmission failure occurred, a parity error was detected by hardware in the IOT.
Initial Actions
Refer to BSD 3.1.
Procedure
Check that P/Js 402 on the MCU PWB (PL 9.1) and P/J 310 on the ESS PWB (PL 9.2) are
securely connected.
If the problem persists reload Firmware (ADJ 9.3.1).