February, 2008
2-597
WorkCentre 5225, 5230
116-334, 116-335
Status Indicator Raps
Launch Version
116-334 ESS NVRAM Data Compare Fail RAP
System Cont detects [ESS-NVRAM with factory settings is installed] or [Illegal ESS-NVRAM
data is occurring].
Initial Actions
Power Off/On
Procedure
As powering OFF then ON after a detection of 116-334 will presumably cause other errors 124-3xx
that indicate various data mismatches between the three locations, resolve one(s) following the
corrective actions for the relevant Fault Code(s).
If 116-334 reoccurs despite powering OFF/ON, disconnect and reconnect the NV-RAM Board,
then turn ON the power.
If the problem persists, replace the NV-RAM Board.
If the problem still persists, replace the mercury battery.
116-335 HDD RAP
The control logic detected that the HDD failed.
Initial Actions
Power Off/On
Procedure
Check the HDD electrical connections (PL 9.2).
If the problem persists perform Hard Disk Diagnostic Program.
If the problem persists replace the HDD (PL 9.2).