Status Indicator Raps
Launch Version
047-211 OCT 1 RAP
BSD-ON:10.6
the OCT Home Sensor 1 did not actuate in time after the OCT1 Motor energized.
Procedure
Manually operate the offset mechanism. The offset mechanism moves smoothly.
YN
Replace the parts that are interfering with operation (PL 6.2).
Execute Component Control [047-205 OCT Home Sensor 1]. Actuate the OCT Home Sensor 1
with paper.
The display changes.
YN
Check the connections of P/J117, P/J613, P/J432. Connections are connected cor-
rectly.
YN
Connect connectors
Check the wire between P/J117 and P/J432 for an open circuit or a short circuit (BSD
10.6 Flag 1/Flag 2).
The wires are conducting without an open circuit or a short cir-
cuit.
YN
Repair the open circuit or short circuit.
Replace the OCT Home Sensor 1 (PL 6.2).
Alternately execute Component Control [047-001 Offset Motor 1 (CW)] and Component Con-
trol [047-005 Offset Motor 1 (CCW)]. The Offset Motor 2 energizes.
YN
Check the connections of P/J432 and P/J206. Connections are connected correctly.
YN
Connect connectors
Check the wire between P/J432 and P/J206 for an open circuit or a short circuit (BSD
10.6 Flag 3).
The wires are conducting without an open circuit or a short circuit.
YN
Repair the open circuit or short circuit.
Measure the resistance of the Offset Motor 1 between J206-1 (COM) and each point of J206-
2/3/4/5 (BSD 10.6 Flag 3).
The resistance is approx. 100Ohm.
YN
Replace the Offset Motor 1 (PL 6.2).
Measure the voltage between the Exit PWB P432-7 (+) and GND (-) (BSD 10.6 Flag 3).
The voltage is approx. +24VDC.
YN
Go to BSD 1.1 and troubleshoot the +24VDC circuit.
Replace the Offset Motor 1 (PL 6.2) If the problem persists, replace the MCU PWB (PL
9.1).
Replace the MCU PWB (PL 9.1).
A