February, 2008
4-188
WorkCentre 5225, 5230
REP 22.5.3
Launch Version
Repairs and Adjustments
REP 22.5.3 Compile Exit Sensor
Parts List on PL 22.5
Removal
WARNING
To avoid personal injury or shock, do not perform repair or adjustment with electrical
power applied to the machine.
1. Remove the A-Finisher from the machine. (REP 22.1)
2. Turn over the A-Finisher.
3. Remove the Bottom Cover. (PL 22.2)
4. Remove the Connector Bracket. (Figure 1)
(1)Release Clamps (3) and remove the wires.
(2)Disconnect Connectors (5).
(3)Remove Screws (2).
(4)Remove Connector Bracket.
Figure 1 Removing the Connector Bracket (0fa42266)
5. Remove the Bottom Plate. (Figure 2)
(1)Release Clamps (5) and remove the wires.
(2)Disconnect Connectors (8).
(3)Release wires from Hooks (4).
(4)Remove Screws (4).
(5)Remove Bottom Plate.
Figure 2 Moving the Bottom Plate (j0fa42267)
6. Remove the Compile Exit Sensor Assembly. (Figure 3)
(1)Remove Screw.
(2)Remove Compile Exit Sensor Assembly.
Figure 3 Removing the Compile Exit Sensor Assembly (j0fa42227)