8.Remove the rotor.
Verifiche e controlli
Check
Rotor
Rotor check - (for circuit opening).
Using an ohmmeter, check resistance between
the commutator rings.
If this does not result, replace the remote control.
Characteristic
Standard resistance:
2.9 ± 0.2 Ω
Rotor check - (for ground).
Make sure there is no continuity between the com-
mutator rings and the rotor casing.
If there is, replace the rotor.
Commutator check.
1. Check the commutator surface for irregularities
(e.g. wear, burning etc.); then replace the rotor.
PORTER 1.3 16V Electrical system