EasyManuals Logo

Lenze 8400 User Manual

Lenze 8400
1590 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #1302 background imageLoading...
Page #1302 background image
Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23 1302
17 Function library
17.1 Function blocks | L_ConvPA_3
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
17.1.44 L_ConvPA_3
This FB converts a position into an analog value.
Inputs
Outputs
Parameters
Function
Designator
Data type
Information/possible settings
dnIn_p
DINT
Input signal
Designator
Data type
Value/meaning
nOut_a
INT
Output signal
Internal limitation to ±199 % (100 % 16384)
Parameters Possible settings Info
C01046/3
0 31 Division factor
•Lenze setting: 1
Note!
Conversion is remainder considered.
/B&RQY3$B
GQ,QBS Q2XWBD
&


nOut_a dnIn_p
1
2
C01046/3
------------------------
=

Table of Contents