11 System bus "CAN on board"
11.2 Possible settings via DIP switch
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
11.2.2 Setting the baud rate
The baud rate can be set via code C00351 or with the DIP switches a to d.
11.2.3 Setting the node address
The node address can be set via code C00350 or with the DIP switches 1 to 64.
The labelling on the housing corresponds to the values of the individual DIP switches for
determining the node address.
The valid address range depends on the number of SDO channels set in C00366
:
1 SDO (Lenze setting): 1 ... 127
2 SDO: 1 ... 63
Note!
All DIP switches (a ... d, 1 ... 64) = OFF (Lenze setting):
At switching on, the settings under code C00350
(node address) and C00351 (baud
rate) will become active.
Preset baud rate: 500 kbps
DIP switch position Baud rate
d c b a
OFF ON OFF ON 20 kbps
OFF OFF ON ON 50 kbps
OFF OFF ON OFF 125 kbps
OFF OFF OFF ON 250 kbps
OFF OFF OFF OFF 500 kbps
OFF ON OFF OFF 1000 kbps*
* From version 11.00.00
Note!
The addresses of the nodes must differ from each other.
All DIP switches (a ... d, 1 ... 64) = OFF (Lenze setting):
At switching on, the settings under code C00350
(node address) and C00351 (baud
rate) will become active.

Table of Contents

Other manuals for Lenze 8400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze 8400 and is the answer not in the manual?

Lenze 8400 Specifications

General IconGeneral
CategoryDC Drives
Series8400
Protection classIP20
Control TypeVector control
CommunicationCANopen, PROFIBUS, Ethernet
Protection FeaturesOvercurrent, overvoltage, undervoltage, overtemperature
Input VoltageAC 230/400/480 V

Related product manuals