Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23 427
7 Technology applications
7.3 TA "actuating drive speed (AC Drive Profile)"
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
7.3.6 AC Drive Profile diagnostic parameters
In the All parameters tab, the parameters for diagnostic purposes listed in the following table are
displayed in the AC Drive Profile category.
7.3.7 Setting parameters (short overview)
Note!
These parameter are set by the EtherNet/IP™ communication module and should not be
written by the user.
Parameters Info Lenze setting
C01350/1 ACDrive: DriveMode 1: Speed mode
C01351/1 ACDrive: Control word -
C01352/1 ACDrive: Status word -
C01353/1 ACDrive: Speed scaling 0
C01353/2
ACDrive: Torque scaling 0
Greyed out = display parameter
Parameters Info Lenze setting
Value Unit
C00012 Accel. time - main setpoint 2.000 s
C00013
Decel. time - main setpoint 2.000 s
C00019
Auto-DCB: Threshold 3 rpm
C00024
LS_DriveInterface: bNActCompare 0.00 %
C00036 DCB braking: Current 50.00 %
C00039/1
Fixed setpoint 1 40.00 %
C00039/2
Fixed setpoint 2 60.00 %
C00039/3 Fixed setpoint 3 80.00 %
C00039/4...15
Fixed setpoint 4 ... 15 0.00 %
C00101/1...15
Add. accel. time 1 ... 15 0.000 s
C00103/1...15
Add. decel. time 1 ... 15 0.000 s
C00105
Decel. time - quick stop 2.000 s
C00106
Auto-DCB: Hold time 0.500 s
C00107
DCB braking: Hold time 999.000 s
C00134
L_NSet_1: Ramp smoothing 0: Off
C00182
L_NSet_1: S-ramp time PT1 20.00 s
C00190 L_NSet_1: Setpoint arithmetic 0: Out = Set
C00220
L_NSet_1: Acceleration time - add. setpoint 0.000 s
C00221
L_NSet_1: Deceleration time - add. setpoint 0.000 s
C00222
L_PCTRL_1: Vp 1.0
C00223
L_PCTRL_1: Tn 400 ms
C00224
L_PCTRL_1: Kd 0.0