8 Basic drive functions (MCK)
8.12 Holding brake control
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
8.12.2.1 Operating mode
For different applications and tasks, different operating modes are available in C02580. The
selected operating mode determines whether the holding brake control is used and how the
holding brake will be switched.
Mode 0: Brake control off
In this mode, brake control is switched off (not active).
•The bMBrakeReleaseOut trigger signal for the holding brake control switching element is set to
FALSE.
•The bMBrakeReleased status signal is set to FALSE.
Mode 11: Manual control
In this mode, brake release and brake application can be directly controlled via the bMBrakeRelease
input without special logic or automatic.
Setting pulse inhibit or controller inhibit has no influence on the bMBrakeReleaseOut trigger
signal for the holding brake control switching element.
After the brake has been activated and the brake application time has expired, the controller is
inhibited automatically by the basic "Holding brake control" function.
Tip!
You can use mode 11 to easily check if the brake switches correctly.
C02589/1 Holding brake: Closing time 100 ms
C02589/2
Holding brake: Release time 100 ms
C02589/3
Holding brake: Waiting time status 100 ms
C02589/4
Holding brake: Ramp FF control 0 ms
C02593/1
Holding brake: Actual value monitoring 0.000 ms
C02593/2
Holding brake: Application delay 0.000 ms
C02610/1
MCK: Holding brake ramp time synchr. 2.000 s
C02607 Holding brake: Status -
C00830/68 MCK: nMBrakeAddValue_a - %
C00833/80 MCK: bMBrakeRelease -
C00833/81 MCK: bMBrakeStartValue2 -
C00833/82 MCK: bMBrakeApplied -
Parameters Info Lenze setting
Value Unit
Greyed out = display parameter
Note!
In the Lenze setting, the mode 0 is preset to get into a safe state after the mains is
switched on.

Table of Contents

Other manuals for Lenze 8400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze 8400 and is the answer not in the manual?

Lenze 8400 Specifications

General IconGeneral
CategoryDC Drives
Series8400
Protection classIP20
Control TypeVector control
CommunicationCANopen, PROFIBUS, Ethernet
Protection FeaturesOvercurrent, overvoltage, undervoltage, overtemperature
Input VoltageAC 230/400/480 V

Related product manuals