Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23 423
7 Technology applications
7.3 TA "actuating drive speed (AC Drive Profile)"
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
7.3.4.8 MCI
Process data assignment for fieldbus communication ( 424)
Connection Assignment Connection Assignment
X101/NC-NO LA_NCtrl.bDriveFail
X5/RFR LA_NCtrl.bFailReset X3/A1U LA_NCtrl.nAuxSetValue_a *
X5/DI1 LA_NCtrl.bJogSpeed1 X3/A1I -
X5/DI2 LA_NCtrl.bJogSpeed2 X3/A2U -
X5/DI3 LA_NCtrl.bSetDCBrake X3/A2I -
X5/DI4 LA_NCtrl.bSetSpeedCcw X3/O1U LA_NCtrl.nMotorSpeedAct_a *
X5/DI5 - X3/O1I -
X5/DI6 - X3/O2U -
X5/DI7 - X3/O2I -
* 10 V ≡ 100 % reference speed (C00011
)
X107/BD1 - X4/DO1 LA_NCtrl.bDriveReady
X107/BD2 - X4/DO2 -
X4/DO3 -
X4
24B 24O
GB DO1
BD2 DO3
GO
BD1 DO2
A2I
AR
COM
A1U
NC
A2U
A1I
NO
X3
DI3
DI2
DI4
DI5
DI6
DI7
GI
24I
DI1
RFR
GA
O1U
O1I
O2U
O2I
X101
24E
CG
CL
CH
X1
+
=
X5
X107
*
LP_MciIn
wCtrl
wIn2
wIn3
DriveControl
SpeedReference
TorqueReference
LP_MciOut
wState
wOut2
wOut3
DriveControlStatus
SpeedActual
TorqueActual
wOut4...16
-
wIn4...16
-
Controller enable / reset error
External
supply
24 V DC
DriveFail
Fixed setpoint 1/3*
Fixed setpoint 2/3*
DC brake*
Direction of rotation CCw*
DriveReady
Actual speed value
Inputs only active if NetCtrl=0
Speed mode:
Torque mode:
Speed setpoint
Torque setpoint
(only if NetRef=0)