9 Diagnostics & error management
9.9 Error messages of the operating system
652
Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
9.9.4 Export error texts
All error texts of the inverter can be exported into a text file (*.txt) for further processing.
The error text is preceded with the corresponding 32-bit error number (no error type) and the
16-bit error number, both as decimal number.
If there is no corresponding 16-bit error number for a 32-bit error number, the field remains
empty.
Example
Output of the German and English error texts:
How to export the error texts into a text file:
1. Go to the Project view in the Context menu of the 8400 HighLine inverter and execute the
Export error texts... command.
2. Define the following options in the Export error texts dialog box:
Output file and memory location
Languages to be exported (German/English/French)
Device/module to be exported
Separator (tabulator or semicolon)
Font (UTF8, standard font or ASCII)
3. Click OK to start the export.
After the export, a message appears indicating whether the export was successful.
Tip!
From version 13.00.00, the 32-bit number of the state-determining error is displayed in
C00162/1
without error type.
If, for instance, the error texts are stored in a master control or on an operator panel, the
error text to be displayed can be detected by reading the C00162/1
code.
32-BitError 16-BitError DE-de EN-en
0 0 No error No error
111 11 Versorgungsspannung Supply voltage
119 / 19
12323 : Motor management / encoder
125 25 E/A integriert I/O integrated
...
26214416 6672 dH10: Lüfterausfall dH10: Fan failure
26214505 6761 dH69: Abgleichdatenfehler dH69: Adjustment fault

Table of Contents

Other manuals for Lenze 8400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze 8400 and is the answer not in the manual?

Lenze 8400 Specifications

General IconGeneral
CategoryDC Drives
Series8400
Protection classIP20
Control TypeVector control
CommunicationCANopen, PROFIBUS, Ethernet
Protection FeaturesOvercurrent, overvoltage, undervoltage, overtemperature
Input VoltageAC 230/400/480 V