5 Motor control (MCTRL)
5.14 Monitoring
306
Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
5.14.7 Motor phase error monitoring before operation
This function extension is available from version 11.00.00!
This extended motor phase failure monitoring can both detect a phase failure on the basis of test
signals and check for the existence of the motor.
The "motor phase error monitoring before operation" is only directly active after controller
enable if
an error response is set in C00597
AND
the motor phase error monitoring is switched on (C2866/2
= "1: Yes").
The following parameters show the cause of the motor phase failure:
C00561/3
: Motor phase U
C00561/4
: Motor phase V
C00561/5
: Motor phase W
Note!
The motor phase error monitoring before operation must not be connected to a rotating
or coasting machine (high compensation currents and effect of the DC injection
braking).
In case of motor control with feedback, no motor phase error monitoring is executed
if the actual speed value is > 10 rpm.
In case of motor control without feedback, the user must ensure that the motor phase
error monitoring will only be executed if the speed is 0.
If the motor is at quick stop and the brake is applied, no motor phase error monitoring is
executed when quick stop is deactivated (same with "0" speed and applied brake).
If the rated current of the connected motor is lower than 10 % of the rated device
current, the motor phase error monitoring can be activated although no motor phase
error has occurred. In this case, the motor phase error monitoring must be switched off
before operation (C2866/2
="0:No").

Table of Contents

Other manuals for Lenze 8400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze 8400 and is the answer not in the manual?

Lenze 8400 Specifications

General IconGeneral
CategoryDC Drives
Series8400
Protection classIP20
Control TypeVector control
CommunicationCANopen, PROFIBUS, Ethernet
Protection FeaturesOvercurrent, overvoltage, undervoltage, overtemperature
Input VoltageAC 230/400/480 V

Related product manuals