8 Basic drive functions (MCK)
8.8 Positioning
590
Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
8.8.2.4 Touch probe positioning
This function extension is available from version 06.00.00!
In case of a touch probe positioning, first the profile is executed according to the set profile
parameters. If a touch probe is detected during the process, it is automatically changed to the profile
defined in the "TP profile" profile parameter. This profile mode is also defined via the mode selection
like in the following profile start processes.
If no valid TP profile is set, the travel request is aborted ("PosStop").
Preconditions for touch probe positioning
The mode of the current profile data set contains the setting "to TP".
For absolute positioning, the home (reference) position must be known.
In the corresponding profile data set, the following profile parameters must be set in addition:
TP profile (C1308/x
)
•TP signal source (C1309/x
)
The touch probe interface is configured such that the selected TP signal source is enabled.
See chapter entitled "Touch probe detection
". ( 357)
Note!
Go to C02810/x and select the edge, the digital input used for the connection of the
touch-probe sensor is to respond. In the Lenze setting of C02810/x
, no touch probe is
detected!

Table of Contents

Other manuals for Lenze 8400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze 8400 and is the answer not in the manual?

Lenze 8400 Specifications

General IconGeneral
CategoryDC Drives
Series8400
Protection classIP20
Control TypeVector control
CommunicationCANopen, PROFIBUS, Ethernet
Protection FeaturesOvercurrent, overvoltage, undervoltage, overtemperature
Input VoltageAC 230/400/480 V

Related product manuals