8 Basic drive functions (MCK)
8.4 Basic settings
528
Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
8.4 Basic settings
8.4.1 Machine parameters
The motor end, among other things, is described by the machine parameters indicated below in
respect of the mechanics used.
For TA "Table positioning"
, you can set the machine parameters in the »Engineer» on the tab headed
Application Parameters on the dialog level Overview Machine parameters:
Tip!
You are provided with more detailed information on the machine parameters "Gearbox
ratio" and "Feed constant" in the following subchapters.
Note!
Setting the machine parameters is a basic prerequisite for the operating modes
"Homing
", "Manual jog" and "Positioning".
The more precisely the machine parameters are set, the better the results of positioning!

Table of Contents

Other manuals for Lenze 8400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze 8400 and is the answer not in the manual?

Lenze 8400 Specifications

General IconGeneral
CategoryDC Drives
Series8400
Protection classIP20
Control TypeVector control
CommunicationCANopen, PROFIBUS, Ethernet
Protection FeaturesOvercurrent, overvoltage, undervoltage, overtemperature
Input VoltageAC 230/400/480 V