EasyManuals Logo

Lenze 8400 User Manual

Lenze 8400
1590 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #637 background imageLoading...
Page #637 background image
Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23 637
9 Diagnostics & error management
9.5 Logbook
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Structure of the semicolon separated list
The list includes the following information:
9.5.6 Storing the logbook in the project
If you want to display the currently available logbook entries at a later date in offline mode, i.e.
without a connection to the inverter, you can store the current logbook in the project.
How to store the logbook in the project:
Go to the Logbook dialog box and click the File in project button.
The logbook with all the entries uploaded up to now is stored in the Engineer project
independent of the set filter criteria.
A logbook of the same device already stored before will be overwritten without querying the
user.
The filter settings are not stored in the project.
When a logbook is filed in the project, the logbook can also be opened in offline mode via the
Logbook button on the Diagnostics tab.
1. Cons. no.
2. Enable
3. Counter
4. Type
5. Subject matter
6. Error text
7. Time stamp
8. Relative time
9. Error number
10. Source - analog value 1
11. Analog value 1
12. Source - digital value 1
13. Digital value 1
14. Source - digital value 2
15. Digital value 2
Note!
Storing the logbook changes the project.
When the project is closed, you are asked to save the changed project.
Only if the changed project is saved, the new logbook entries stored in the project
remain stored.

Table of Contents

Other manuals for Lenze 8400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze 8400 and is the answer not in the manual?

Lenze 8400 Specifications

General IconGeneral
CategoryDC Drives
Series8400
Protection classIP20
Control TypeVector control
CommunicationCANopen, PROFIBUS, Ethernet
Protection FeaturesOvercurrent, overvoltage, undervoltage, overtemperature
Input VoltageAC 230/400/480 V

Related product manuals