3 Commissioning
3.4 Trouble-shooting during commissioning
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
3.4 Trouble-shooting during commissioning
When the »Engineer« is used, trouble during commissioning can be detected and eliminated
conveniently. Proceed as follows:
• Check whether error messages appear in the »Engineer«.
•On the Diagnostics tab, relevant actual states of the inverter and pending error messages are
displayed in a well-arranged visualisation.
• Check the input terminals for their corresponding setpoints.
•The Terminal assignment tab displays the current input/output signals.
• Check the signal flow of the application.
• For this purpose, click the Signal flow button on the Application parameter tab. The displayed
signal flow shows active setpoints and their further processing.
Related topics:
Diagnostics & error management
( 623)
LED status displays
( 624)
Error messages of the operating system
( 647)
3.5 Commissioning wizard 8400
This function extension is supported by the »Engineer« from version 2.15 onwards!
The commissioning wizard 8400 serves to carry out a guided commissioning of the inverter based
on the Lenze setting of the parameters. The set parameters can then be saved in the inverter with
mains failure protection.
Note!
Take all the necessary safety precautions before you carry out the following
commissioning steps and switch the device on!
Safety instructions with regard to commissioning
( 52)