10 Oscilloscope function
682 Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
10 Oscilloscope function
This function extension is available from version 12.00.00!
The oscilloscope function integrated in the 8400 HighLine can be used as support for
commissioning, maintenance, and troubleshooting. It is operated via a user interface in the
engineering tool.
Typical applications
Graphic display of measured variable (e.g. speed setpoint, actual speed value and torque)
Detection of process values without additional measuring instruments (e.g. oscilloscope,
voltmeter and ammeter)
Convenient documentation for fine tuning of control circuits or parameter changes of the
inverter
Special features
Recording and saving of measured values in the 8400 HighLine
Simultaneous measuring on acht independent channels
Measuring fast and slow signals by means of adjustable sample rate
Triggering on a channel, an application variable or system event
Detecting measured values before and after the trigger event
Transferring measured values to the Engineering PC for the purpose of graphic display and
evaluation in the engineering tool
The measured values represented in the form of interpolated curves can be optionally shown
and hidden, represented in any colour or overlaid with the signal characteristics of other
variables recorded.
Cursor and zoom function for the measurement analysis
Saving & loading oscilloscope configurations on the Engineering PC
Export of measured values via the clipboard for further processing
Linking channel values with arithmetic operations (addition, subtraction and multiplication)
Simple signal analysis by frequency transformation of time signals with FFT ("Fast Fourier
Transformation").

Table of Contents

Other manuals for Lenze 8400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze 8400 and is the answer not in the manual?

Lenze 8400 Specifications

General IconGeneral
CategoryDC Drives
Series8400
Protection classIP20
Control TypeVector control
CommunicationCANopen, PROFIBUS, Ethernet
Protection FeaturesOvercurrent, overvoltage, undervoltage, overtemperature
Input VoltageAC 230/400/480 V

Related product manuals