6 I/O terminals
6.3 Analog terminals
352
Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
6.3.1.1 Signal adaptation by means of characteristic
This function extension is only available from version 04.00.00!
According to the illustration below, an individual characteristic can be parameterised for the analog
inputs via the subcodes of C00010
and C00020 to provide different slopes and a dead band. Here,
the input signal corresponds to the X axis and the output signal corresponds to the Y axis:
[6-5] Characteristic for analog inputs
In the »Engineer«, there is a parameterising dialog for entering the characteristic. This dialog also
displays the set characteristic graphically.
199.99 %
y
max
-y
max
-x
max
x
max
y
min
-y
min
199.99 %
-199.99 %
-199.99 %
Parameters Info Lenze setting
Value Unit
C00010/1 AIN1: (+y0) = min 0.00 %
C00010/2
AIN1: (+x0) = Dead band 1.00 %
C00010/3
AIN1: (-y0) = (-min) 0.00 %
C00010/4 AIN1: (-x0) = (-Dead band) 1.00 %
C00010/5
AIN1: (+ymax) 199.99 %
C00010/6
AIN1: (+xmax) 199.99 %
C00010/7 AIN1: (-ymax) 199.99 %
C00010/8
AIN1: (-xmax) 199.99 %
C00020/1
AIN2: (+y0) = min 0.00 %
C00020/2 AIN2: (+x0) = Dead band 1.00 %
C00020/3
AIN2: (-y0) = (-min) 0.00 %
C00020/4
AIN2: (-x0) = (-Dead band) 1.00 %
C00020/5 AIN2: (+ymax) 199.99 %
C00020/6
AIN2: (+xmax) 199.99 %
C00020/7
AIN2: (-ymax) 199.99 %
C00020/8
AIN2: (-xmax) 199.99 %

Table of Contents

Other manuals for Lenze 8400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze 8400 and is the answer not in the manual?

Lenze 8400 Specifications

General IconGeneral
CategoryDC Drives
Series8400
Protection classIP20
Control TypeVector control
CommunicationCANopen, PROFIBUS, Ethernet
Protection FeaturesOvercurrent, overvoltage, undervoltage, overtemperature
Input VoltageAC 230/400/480 V

Related product manuals