Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23 577
8 Basic drive functions (MCK)
8.7 Manual jog
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
8.7.1.4 Time-based start of second speed
If this function has been activated by means of bit 1 in C01230 and a waiting time > "0 s" has been
set in C01235/1
, an automatic change-over to manual jog speed 2 takes place when the manual jog
function is activated and after the waiting time has expired.
• When the waiting time is set = 0 s, the automatic change-over is deactivated.
[8-31] Time-based start of second speed
Tip!
By leaving the corresponding button for manual jog pressed down for longer than the
waiting time and parameterising manual jog speed 2 so that it is higher than manual jog
speed 1, you can enable longer distances to be travelled by means of manual jogging with
this function.
Time-based start deactivated
(C01230
- bit 1 = 0; Lenze setting)
Time-based start activated
(C01230
- bit 1 = 1)
C01231/1
: Manual jog: Speed 1
C01231/2
: Manual jog: Speed 2
C01235/1
: Waiting time 2nd speed (Lenze setting: 5 s)