Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23 1362
17 Function library
17.1 Function blocks | L_DFSET_1
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
17.1.73.4 Synchronising slave drive to master drive
If an angular synchronism of the drives is required (e.g. in printing units), the slave drives must be
positioned to the master position since the FB L_DFSET as a master value can only receive and
process one relative signal. The FB L_DFSET receives the master value via a real-time capable
MotionBus as the system bus (CAN).
For synchronisation purposes, the slave drive is informed cyclically or once about its drive position
by a pulse generated by the master drive. This pulse is either the zero pulse of the master feedback
or the edge of a touch probe sensor. Moreover, a pulse must be generated by the slave drive. Only if
the FB L_DFSET receives both signals, it can execute a synchronisation.
Synchronisation mode - mark correction
For synchronisation, the following modes are available in C01075/1
:
Mode Info
0 Synchronisation inactive Lenze setting
1 Permanent synchronisation without enable via the
bZeroPulse input
Correction is executed over the shortest possible
path.
The synchronisation only takes place after 2 setpoint
pulses have been received at the bSetTPReceived
input.
(required pulse order: set-actual-set)
See illustration [17-37]
. ( 1363)
2 Permanent synchronisation only with enable via the
bZeroPulse input
• When bZeroPulse is set to TRUE, a permanent
zero pulse/touch probe synchronisation is
executed.
Correction is executed over the shortest possible
path.
10 One-time synchronisation only with enable via the
bZeroPulse input
An angular difference is compensated over the
shortest possible path.
11 One-time synchronisation only with enable via the
bZeroPulse input
An angle difference is compensated in CW
direction.
12 One-time synchronisation only with enable via the
bZeroPulse input
An angular difference is compensated in CCW
direction.
13 One-time synchronisation only with enable via the
bZeroPulse input
An angular difference is compensated over the
shortest possible path.
Synchronisation takes place after the first setpoint
pulse has been received at the bSetTPReceived input
and/or actual value pulse at the bActTPReceived
input.
(Required clock sequence: Set/actual or actual/set)
See illustration [17-38]
. ( 1363)

Table of Contents

Other manuals for Lenze 8400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze 8400 and is the answer not in the manual?

Lenze 8400 Specifications

General IconGeneral
CategoryDC Drives
Series8400
Protection classIP20
Control TypeVector control
CommunicationCANopen, PROFIBUS, Ethernet
Protection FeaturesOvercurrent, overvoltage, undervoltage, overtemperature
Input VoltageAC 230/400/480 V

Related product manuals