Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23 1454
17 Function library
17.1 Function blocks | L_OffsetGainPhiP_2
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
17.1.127 L_OffsetGainPhiP_2
This FB can add an offset to an angle signal and amplify it afterwards.
The internal calculations (addition and subtraction) are carried out with 32 bits without
overflow/underflow. Division is not remainder considered.
Offset and gain are selected via parameters.
The value provided at the dnOut_p output is internally limited to ±2
31
-1.
Inputs
Outputs
Parameters
Function
Designator
Data type
Information/possible settings
dnIn_p
DINT
Input signal
Designator
Data type
Value/meaning
dnOut_p
DINT
Output signal
Internal limitation to ±2
31
-1 (±2147483647)
Parameters Possible settings Info
C00673/2
-2147483647 Incr. 2147483647 Offset
Lenze setting: 0 incr.
C00674/2
-2147483647 2147483647 Gain factor
Scaling:
65535 gain factor 1
Lenze setting: 65536
/B2IIVHW*DLQ3KL3B
GQ,QBS GQ2XWBS

r

2IIVHW *DLQ
& &
dnOut_p dnIn_p Offset+()Gain factor=

Table of Contents

Other manuals for Lenze 8400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze 8400 and is the answer not in the manual?

Lenze 8400 Specifications

General IconGeneral
CategoryDC Drives
Series8400
Protection classIP20
Control TypeVector control
CommunicationCANopen, PROFIBUS, Ethernet
Protection FeaturesOvercurrent, overvoltage, undervoltage, overtemperature
Input VoltageAC 230/400/480 V

Related product manuals