7 Technology applications
7.5 TA "Switch-off positioning"
Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23 475
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
7.5.3 Terminal assignment of the control modes
The following comparison provides information about which inputs/outputs of the application block LA_SwitchPos are interconnected to the
digital and analog input/output terminals of the inverter in the different control modes.
Control mode (C00007)
10: Terminals 0 12: Terminals 2 14: Terminals 11 16: Terminal 16 20: Keypad 21: PC 30: CAN 40: MCI
Digital input terminals
X5/RFR Controller enable Controller enable / Reset of error message
bFailReset
X5/DI1 Fixed setpoint 1/3
bJogCtrlJog1
Stop function 1
bJogCtrlStop1
Fixed setpoint 1/3
bJogCtrlJog1
- - Stop function 1
bJogCtrlStop1
X5/DI2 Fixed setpoint 2/3
bJogCtrlJog2
Stop function 2
bJogCtrlStop2
Selection: Pre-switch off
1
bJogCtrlSlowDown 1
Fixed setpoint 2/3
bJogCtrlJog2
- - Selection: Pre-switch off 1
bJogCtrlSlowDown 1
X5/DI3 Reset error message
bFailReset
CW rotation quick stop
bRLQCw
Selection: Switch-off position 1
bJogCtrlInputSel1
CW rotation quick stop
bRLQCw
- - Stop function 2
bJogCtrlStop2
X5/DI4 Change of direction of
rotation
bSetSpeedCcw
CCW rotation quick stop
bRLQCcw
Selection: Switch-off position 2
bJogCtrlInputSel2
CCW rotation quick stop
bRLQCcw
- - Selection: Pre-switch off 2
bJogCtrlSlowDown 2
X5/DI5
- - Stop function 2
bJogCtrlStop2
- - - Stop function 3
bJogCtrlStop3
X5/DI6
- - Selection: Pre-switch off
2
bJogCtrlSlowDown 2
- - - Selection: Pre-switch off 3
bJogCtrlSlowDown 3
X5/DI7
- - - - - - - -
Analog input terminals
X3/A1U, A1I Main speed setpoint
nMainSetValue_a
10 V 100 % reference speed (C00011)
- - Additional speed setpoint
nAuxSetValue_a
10 V 100 % reference speed (C00011
)
X3/A2U, A2I
- - - - - - - -
Digital output terminals
X4/DO1 ... DO3
- - - - - - - -
X107/BD1, BD2 Control of the holding brake
bMBrakeReleaseOut
X101/COM, NO
- - - - - - - -
Analog output terminals
X3/O1U, O1I
- - - - - - - -
X3/O2U, O2I

Table of Contents

Other manuals for Lenze 8400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze 8400 and is the answer not in the manual?

Lenze 8400 Specifications

General IconGeneral
CategoryDC Drives
Series8400
Protection classIP20
Control TypeVector control
CommunicationCANopen, PROFIBUS, Ethernet
Protection FeaturesOvercurrent, overvoltage, undervoltage, overtemperature
Input VoltageAC 230/400/480 V