EasyManuals Logo

Lenze 8400 User Manual

Lenze 8400
1590 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #390 background imageLoading...
Page #390 background image
7 Technology applications
7.2 TA "Actuating drive speed"
390
Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
7.2.3.5 Keypad
Connection Assignment Connection Assignment
X101/NC-NO LA_NCtrl.bDriveFail
X5/RFR LA_NCtrl.bFailReset X3/A1U -
X5/DI1 - X3/A1I -
X5/DI2 - X3/A2U -
X5/DI3 - X3/A2I -
X5/DI4 - X3/O1U LA_NCtrl.nMotorSpeedAct_a *
X5/DI5 - X3/O1I -
X5/DI6 - X3/O2U -
X5/DI7 - X3/O2I -
* 10 V 100 % reference speed (C00011
)
X107/BD1 - X4/DO1 LA_NCtrl.bDriveReady
X107/BD2 - X4/DO2 -
X4/DO3 -
X4
24B 24O
GB DO1
BD2 DO3
GO
BD1 DO2
A2I
AR
COM
A1U
NC
A2U
A1I
NO
X3
DI3
DI2
DI4
DI5
DI6
DI7
GI
24I
DI1
RFR
GA
O1U
O1I
O2U
O2I
X101
24E
Quick commissioning
SAVE
Par1 Quick commissioning
Terminals
Keypad
SAVE
Par1 8400 HighLineC
User - Menu
Logbook
Go to param
Quick commissioning
C2/1
C7
C728
C11
C12
C13
C15
C16
C22
C87
C89
C39/1
C727/3
C727/4
C51
C54
+
=
CG
CL
CH
X1
X5
X107
Engineer:
Keypad:
Actual speed value
Controller enable
/ reset error
DriveReady
External
supply
24 V DC
All parameters
Quick commissioning
Terminal
Keypad
DriveFail

Table of Contents

Other manuals for Lenze 8400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze 8400 and is the answer not in the manual?

Lenze 8400 Specifications

General IconGeneral
CategoryDC Drives
Series8400
Protection classIP20
Control TypeVector control
CommunicationCANopen, PROFIBUS, Ethernet
Protection FeaturesOvercurrent, overvoltage, undervoltage, overtemperature
Input VoltageAC 230/400/480 V