Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23 327
6 I/O terminals
6.1 Digital input terminals
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
6.1.1.2 Using DI1(6) and DI2(7) as frequency inputs
General information on using the input terminals as frequency inputs
The frequency inputs serve to detect HTL encoders with any number of increments and single-track
and two-track signals. Single-track signals can be evaluated with or without rotation signal.
Example of DI6/DI7 (in accordance with the preceding note):
Encoder increment: 512 pulses / motor revolution
Reference speed (C00011): 1500 rpm
Speed setpoint: 100 %
•Result:
The speed or the number of increments is too high!
Tip!
From version 06.00.00 onwards, the LS_DigitalInput
system block can also provide the
encoder position. Detailed information on this topic is provided in chapter "Output of the
encoder position of the DI1/DI2 frequency input". ( 339)
Note!
Make sure that, when motor control with speed feedback is in use, the maximum
input frequency of the respective input terminal is not exceeded.
•DI1/DI2: f
max
= 100 kHz (from version 11.00.00: f
max
= 200 kHz)
•DI6/DI7: f
max
= 10 kHz
If the encoder signal is used as an actual speed value:
Number of encoder pulses / revolution 8192!
Input frequency
1500 rpm
60 s
-------------------------
512 pulses × 12800 pulses/s 12.8 kHz===

Table of Contents

Other manuals for Lenze 8400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze 8400 and is the answer not in the manual?

Lenze 8400 Specifications

General IconGeneral
CategoryDC Drives
Series8400
Protection classIP20
Control TypeVector control
CommunicationCANopen, PROFIBUS, Ethernet
Protection FeaturesOvercurrent, overvoltage, undervoltage, overtemperature
Input VoltageAC 230/400/480 V

Related product manuals