2 Introduction: Parameterising the inverter
2.5 Device identification
50
Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
2.5 Device identification
For device identification, any device name (e.g. wheel drive) with max 32 characters can be set in
C00199/1
for the inverter and saved in the memory module with mains failure protection.
2.5.1 Automatic acceptance of the device name in the »Engineer«
If a device name is assigned in C00199/1 and the inverter in the »Engineer« is added to the project
via the Insert Insert device detected online... function, the device name stored in C00199/1
(here:
wheel drive) is used as device designation in the Project view instead of the type (8400 HighLine):
This mechanism also functions in reverse direction:
If you rename the inverter in the project view via <F2>, you will be asked afterwards if you want to
take over the changed name in C00199/1
:
2.5.2 Extended item designation
This function extension is available from version 12.00.00!
In C00199/2...5
, four texts à max. 32 characters can be set for item designation and saved in the
memory module safe against mains failure. These additional subcodes are not dependent on the
previously described text acceptance mechanism in the »Engineer« for the device name (C00199/1
).