EasyManuals Logo

Lenze 8400 User Manual

Lenze 8400
1590 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #426 background imageLoading...
Page #426 background image
7 Technology applications
7.3 TA "actuating drive speed (AC Drive Profile)"
426
Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
7.3.5.2 Scaling of speed and torque values
Scaling of the speed values
The speed setpoint is defined by the bus in [rpm]. The conversion then takes place in the inverter as
all speed-related signals are processed to a reference variable in percent. An adjustable scaling
factor serves to make an additional scaling.
For the output of the actual speed value to the bus, the following conversion is made:
Scaling of the torque values
The torque setpoint is defined by the bus in [Nm]. The conversion then takes place in the inverter as
all torque-related signals are processed to a reference variable in percent. An adjustable scaling
factor serves to make an additional scaling.
For the output of the actual torque value to the bus, the following conversion is made:
Equation for scaling the speed setpoint
Parameters Name Description
C00011 Appl.: Reference speed Reference variable for speed-related signals
C01353/1
ACDrive: Speed scaling In the Lenze setting "0", no scaling takes place (2
0
=1)
Equation for scaling the actual speed value
Parameters Name Description
C00011 Appl.: Reference speed Reference variable for speed-related signals
C01353/1
ACDrive: Speed scaling In the Lenze setting "0", no scaling takes place (2
0
=1)
Equation for scaling the torque setpoint
Parameters Name Description
C00057 Maximum torque Reference variable for torque-related signals
C01353/2
ACDrive: Torque scaling In the Lenze setting "0", no scaling takes place (2
0
=1)
Equation for scaling the actual torque
Parameters Name Description
C00057 Maximum torque Reference variable for torque-related signals
C01353/2
ACDrive: Torque scaling In the Lenze setting "0", no scaling takes place (2
0
=1)
Speed setpoint
Application
Speed setpoint
Bus
[rpm]
16384
Reference speed [rpm]
----------------------------------------------------------
1
2
Scaling factor
--------------------------------
⋅⋅=
Actual speed value
Bus
[rpm] Actual speed value
Application
Reference speed [rpm]
16384
----------------------------------------------------------
2
Scaling factor
⋅⋅=
Torque setpoint
Application
Torque setpoint
Bus
[Nm]
16384 100
Maximum torque [0.01 Nm]
-------------------------------------------------------------------------
1
2
Scaling factor
--------------------------------
⋅⋅=
Actual torque
Bus
[Nm] Actual torque
Application
Maximum torque [0.01 Nm]
16384 100
-------------------------------------------------------------------------
2
Scaling factor
⋅⋅=

Table of Contents

Other manuals for Lenze 8400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze 8400 and is the answer not in the manual?

Lenze 8400 Specifications

General IconGeneral
CategoryDC Drives
Series8400
Protection classIP20
Control TypeVector control
CommunicationCANopen, PROFIBUS, Ethernet
Protection FeaturesOvercurrent, overvoltage, undervoltage, overtemperature
Input VoltageAC 230/400/480 V

Related product manuals