7 Technology applications
7.3 TA "actuating drive speed (AC Drive Profile)"
418
Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
7.3.4.3 Terminals 11
Connection Assignment Connection Assignment
X101/NC-NO LA_NCtrl.bDriveFail
X5/RFR LA_NCtrl.bFailReset X3/A1U LA_NCtrl.nAuxSetValue_a *
X5/DI1 LA_NCtrl.bSetSpeedCcw X3/A1I -
X5/DI2 LA_NCtrl.bSetDCBrake X3/A2U -
X5/DI3 LA_NCtrl.bMPotUp X3/A2I -
X5/DI4 LA_NCtrl.bMPotDown X3/O1U LA_NCtrl.nMotorSpeedAct_a *
X5/DI5 - X3/O1I -
X5/DI6 - X3/O2U -
X5/DI7 - X3/O2I -
* 10 V ≡ 100 % reference speed (C00011
)
X107/BD1 - X4/DO1 LA_NCtrl.bDriveReady
X107/BD2 - X4/DO2 -
X4/DO3 -
X4
24B 24O
GB DO1
BD2 DO3
GO
BD1 DO2
A2I
AR
COM
A1U
NC
A2U
A1I
NO
X3
DI3
DI2
DI4
DI5
DI6
DI7
GI
24I
DI1
RFR
GA
O1U
O1I
O2U
O2I
X101
24E
+
=
CG
CL
CH
X1
X5
X107
Controller enable / reset error
Direction of rotation Ccw
DC brake active
Speed higher
Speed lower
Motor
potentiometer
External
supply
24 V DC
DriveFail
DriveReady
Actual speed value
Speed mode:
Torque mode:
Speed setpoint