EasyManuals Logo

Lenze 8400 User Manual

Lenze 8400
1590 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #182 background imageLoading...
Page #182 background image
5 Motor control (MCTRL)
5.5 V/f characteristic control - energy-saving (VFCplusEco)
182
Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
5.5.4.2 Adapting the slope limitation for lowering the Eco function
The ramp set in C00982 for voltage reduction serves as slope limitation in order to prevent that
voltage is suddenly applied to the motor when the Eco function is deactivated. Otherwise, the
overvoltage limitation (Imax, Clamp) would be activated.
This ramp is, depending on the device, pre-initialised to approx. the triple rotor time constant.
An adaptation of this parameter is not required.
When the Eco function is switched off, a quick reaction (high dynamic performance) is required, but
with a low current overshoot and a small torque jump. Thus, the Lenze setting of C00982
is a
compromise regarding the switch-off of the Eco function (voltage reduction = 0).
To increase the dynamics when switching off the Eco function:
Reduce setting in C00982
.
(Current compensation actions increase when the Eco function is switched off.)
In order to reduce current compensation actions when switching off the Eco function:
Increase setting in C00982
.
(The dynamics when switching off the eco function is reduced)
5.5.4.3 Optimising the cos/phi controller
With the Lenze setting, the cosϕ controller is set such that usually no adaptation is required for all
power ratings and application cases.
Behaviour Remedy/recommendation
The cosϕ actual value (C00979/1
) varies greatly. Reduce gain Vp (C00975) and reset time Ti (C00976).
The cosϕ actual value (C00979/1
) is permanently lower
than the cosϕ setpoint (C00979/2
).
Increase gain Vp (C00975
) and reset time Ti (C00976).

Table of Contents

Other manuals for Lenze 8400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze 8400 and is the answer not in the manual?

Lenze 8400 Specifications

General IconGeneral
CategoryDC Drives
Series8400
Protection classIP20
Control TypeVector control
CommunicationCANopen, PROFIBUS, Ethernet
Protection FeaturesOvercurrent, overvoltage, undervoltage, overtemperature
Input VoltageAC 230/400/480 V

Related product manuals