7 Technology applications
7.5 TA "Switch-off positioning"
476
Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
7.5.3.1 Terminals 0
Connection Assignment Connection Assignment
X101/NC-NO -
X5/RFR - X3/A1U LA_SwitchPos.nMainSetValue_a
10 V ≡ 100 % reference speed (C00011
)
X5/DI1 LA_SwitchPos.bJogCtrlJog1 X3/A1I
X5/DI2 LA_SwitchPos.bJogCtrlJog2 X3/A2U -
X5/DI3 LA_SwitchPos.bFailReset X3/A2I -
X5/DI4 LA_SwitchPos.bSetSpeedCcw X3/O1U -
X5/DI5 - X3/O1I -
X5/DI6 - X3/O2U -
X5/DI7 - X3/O2I -
X107/BD1 LA_SwitchPos.bMBrakeReleaseOut X4/DO1 -
X107/BD2 - X4/DO2 -
X4/DO3 -
X5
A2I
AR
COM
CG
A1U
NC
CL
A2U
A1I
NO
CH
X107 X4
X3
DI3
DI2
DI4
DI5
DI6
DI7
GI
24I
DI1
RFR
24B 24O
GB DO1
BD2 DO3
GO
BD1 DO2
GA
O1U
O1I
O2U
O2I
X101
X1
24E
+
+
=
=
+
Fixed setpoint 1/3
Controller enable
Fixed setpoint 2/3
Reset error
Change of direction of rotation
External 24 V DC
supply
Speed
setpoint
Brake released