February, 2008
2-78
WorkCentre 5225, 5230
005-305, 005-306
Launch Version
Status Indicator Raps
005-305 CVT Feeder Cover Interlock Open (running) RAP
The system detected that the DADF Interlock was opened while the DADF was running (RUN/
SUSPEND).
Initial Actions
• Refer to BSD 1.3.
Procedure
Check opening/closing of the Feeder Cover. The Feeder Cover can be opened/closed.
YN
Reinstall the Feeder Cover correctly.
Check installation of the DADF Interlock Switch. The DADF Interlock Switch is installed cor-
rectly.
YN
Install the DADF Interlock Switch correctly.
Execute Component Control[005-212 DADF Interlock Switch]. Open and close the Feeder
Cover. The display changes.
YN
Check the connections of P/J753, F1 and F2. P/J753, F1 and F2 are connected cor-
rectly.
YN
Connect P/J753, F1 and F2.
Check the wire between J753 and F1, and between J753 and F2 for an open circuit or a
short circuit (BSD 1.3 Flag 7/Flag 8).
The wires between J753 and F1, and between
J753 and F2 are conducting without an open circuit or a short circuit.
YN
Repair the open circuit or short circuit.
Check the conductivity of the DADF Interlock Switch (PL 15.7) between J753-2 and J753-
1 (BSD 1.3 Flag 7/Flag 8).
The wire between J753-2 and J753-1 is connecting suc-
cessfully when the DADF Interlock Switch contact is closed, and is insulated when
the contact is opened.
YN
Replace the DADF Interlock Switch (PL 15.7).
Replace the DADF PWB (PL 15.3).
Replace the DADF PWB (PL 15.3).
005-306 Tray Interlock Open RAP
Tray Interlock Open during DADF operation detected.
Procedure
To ensure that the Tray is Closed. Check the connections between the Tray Interlock Sensor
and the DADF PWB. If OK, replace the Tray Interlock Sensor. If the problem persists, replace
the DADF PWB (PL 15.3).