February, 2008
2-154
WorkCentre 5225, 5230
013-212, 013-213
Launch Version
Status Indicator Raps
013-212 Booklet Staple Move Position SNR ON Fail RAP
BSD-ON:12.25
Booklet Staple Move Position SNR does not turn on within designated time period
Initial Actions
Power Off/On
Ensure the Staple Head is free from obstructions
Procedure
Check the Staple Move Home Sensor for the following:
• wiring
• connections
• operation
• voltage
013-213 Booklet Staple Move Position SNR OFF Fail RAP
Booklet Staple Move Position SNR does not turn off within designated time period
Initial Actions
Power Off/On
Ensure the Staple Head is free from obstructions
Procedure
Check the Staple Move Home Sensor for the following:
• wiring
• connections
• operation
• voltage