February, 2008
2-670
WorkCentre 5225, 5230
124-316, 124-317
Launch Version
Status Indicator Raps
124-316 Product Mode RAP
BSD-ON:3.6
There is an error in product mode of operation.
Procedure
Perform GP 4 Replacing Billing PWBs.
If the problem persists replace the MCU PWB (PL 9.1)
If the problem persists replace the ESS PWB (PL 9.2).
124-317 All Product Mode RAP
BSD-ON:3.6
There is an error in all modes of product operation.
Procedure
Perform GP 4 Replacing Billing PWBs.
If the problem persists replace the MCU PWB (PL 11.1)
If the problem persists replace the ESS PWB (PL 9.2).