123-372, 123-373
Launch Version
Status Indicator Raps
123-372 Interface Sequence RAP
The initialization command from the Controller was not sent within the specified time.
Initial Actions
Power Off/On
Procedure
Disconnect and reconnect the electrical connections on the UI PWB (PL 11.2) and P/J388 on
the ESS PWB (PL 9.2)
If the problem persists reload Software (ADJ 9.3.1).
If the problem persists replace the ESS PWB (PL 9.2).
123-373 Channel RAP
There is an error in the channel sent from the Controller.
Initial Actions
Power Off/On
Procedure
Disconnect and reconnect the electrical connections on the UI PWB (PL 11.2) and P/J388 on
the ESS PWB (PL 9.2)
If the problem persists reload Software (ADJ 9.3.1).
If the problem persists replace the ESS PWB (PL 9.2).