February, 2008
2-327
WorkCentre 5225, 5230
024-356, 024-362
Status Indicator Raps
Launch Version
024-356 IOT-ESS Communication Failure 16 RAP
A transmission failure is received, an overrun error was detected by hardware of the UART.
Initial Actions
Refer to BSD 3.1, 16.1.
Procedure
Check that P/Js 402 on the MCU PWB (PL 9.1) and P/J 310 on the ESS PWB (PL 9.2) are
securely connected.
If the problem persists reload Firmware (ADJ 9.3.1).
024-362 Page Sync Illegal Start RAP
During IOT output, before the output data was written to FIFO Full, Page Sync became active.
Even though the system is not easily affected by noise, extreme noise may be the cause.
Initial Actions
Refer to BSD 3.1, 16.1.
Procedure
Check that P/Js 402 on the MCU PWB (PL 9.1) and P/J 310 on the ESS PWB (PL 9.2) are
securely connected.
If the problem persists reload Firmware (ADJ 9.3.1).