February, 2008
2-645
WorkCentre 5225, 5230
123-328, 123-329
Status Indicator Raps
Launch Version
123-328 UI Internal Range RAP
UI software failure and a coordinate value outside the range of the display screen is detected.
Initial Actions
Power Off/On
Procedure
Disconnect and reconnect the electrical connections on the UI PWB (PL 11.2) and P/J388 on
the ESS PWB (PL 9.2)
If the problem persists reload Software (ADJ 9.3.1).
If the problem persists replace the UI PWB (PL 11.2).
If the problem persists replace the ESS PWB (PL 9.2)
123-329 UI Coordinates RAP
UI software failure and a coordinate value that cannot be displayed is detected.
Initial Actions
Power Off/On
Procedure
Disconnect and reconnect the electrical connections on the UI PWB (PL 11.2) and P/J388 on
the ESS PWB (PL 9.2)
If the problem persists reload Software (ADJ 9.3.1).
If the problem persists replace the UI PWB (PL 11.2).
If the problem persists replace the ESS PWB (PL 9.2)